Back to Other

Hanna Instruments HI 97711 Portable Photometer

349,00 

Free and Total Chlorine Photometer

SKU: HI 97711 Category:

Description

HI-97711 Free and Total Chlorine Photometer combines accuracy and ease of use in a simple, portable design. The advanced optical system provides lab-quality accuracy while its user-friendly design is easy for any user making it the perfect photometer for your water quality testing needs. The HI-97711 meter measures free and total chlorine in water samples from 0.00 to 5.00 mg/L (ppm).
  • No warm up time needed before taking a measurement.
  • Tutorial mode for easy step-by-step instructions.
  • Uses either powder or cost saving liquid reagents.

Better Features for Better Testing Let your photometer guide you through setup, calibration, and testing with on-screen tutorials and animations so you always know the next step. Simply access Tutorial Mode at any stage in the setup or measurement process with the dedicated help key.

The auto-off feature prolongs battery life for peace-of-mind and energy savings if the meter is accidentally left on. When the battery level is below 10%, a warning symbol will blink to indicate low battery condition. When low battery power may affect your results, the meter will shut down to avoid erroneous readings caused by low battery level.

Data Logging Missed a measurement? No need to worry because your photometer will automatically log the last 50 measurements. The results can be viewed instantly using the Log Recall Menu.

CAL Check Validation Hanna’s exclusive CAL Check feature provides a stress-free, straightforward way to ensure your photometer is working properly. Simply insert the certified CAL Check standards and let your meter guide you through validation. If your photometer is out of specification for any reason, simply calibrate to your standard.

Advanced Optical System A Light Emitting Diode (LED) provides more light while using less power and a narrow band interference filter results in more accurate and repeatable readings.

Built Better Designed to withstand the knocks, drops, and spills of real life, the new IP67 body ensures top performance in any environment. Internal optics are sealed from outside dust, dirt, and water. In addition, it floats, just in case you drop your meter in water. This photometer uses an exclusive positive‑locking system to ensure that the cuvettes are placed into the holder in the same position for accurate readings every time.

Portable Design Made to fit comfortably in your hand for on-the-go testing or sit on a table for benchtop use, a backlit LCD display provides at-a-glance readings from any angle, day or night. The supplied AA batteries provide life for more than 800 measurements.

Each HI-97711 is supplied with: 2 pcs. Sample cuvette, 2 pcs. Sample cap, 2 pcs. Plastic stopper, 3 pcs. Alkaline batteries 1.5V, Instruction manual and Meter quality certificate.

Specification Detail
Chlorine, Free & Total Range 0.00 to 5.00 mg/L
Chlorine, Free & Total Resolution 0.01 mg/L
Chlorine, Free & Total Accuracy ±0.03 mg/L ±3% of reading at 25 °C
Chlorine, Free & Total Method Adaptation of the EPA DPD method 330.5
Light Source light emitting diode
Light Detector silicon photocell
Bandpass Filter Bandwidth 8 nm
Bandpass Filter Wavelength Accuracy ±1.0 nm
Logging 50 readings (auto logging)
Power Supply Alkaline 1.5 V AA (3 pcs.)
Battery Life > 800 measurements (without backlight)
Auto-off After 15 minutes of inactivity (30 minutes before a READ measurement)
Environment 0 to 50 °C; 0 to 100% RH, non‑serviceable
Dimensions 142.5 x 102.5 x 50.5 mm
Weight 380 g

 

Specifications